Case C :The transformation of the dust removal system in the dust control transformation projectof the raw material distribution and feeding system of a smelter of an iron and steel grouprequires that the concentration after discharge is <10mg/m3.
| Project | Unit | Date |
| Flue Gas Purification Treatment Air Volume | M3/h | 32200 |
| Inlet dust concentration | g/m3 | <50 |
| Metal filter bag specifications | mm | OD130x2450 |
| Number of filter bags | Pcs | 490 |
| Filter wind speed | m/min | ≤1.1 |
| Cleaning pressure | Mpa | <0.5 |
| Flue gas temperature | °C | Room temperature |
| Instantaneous maximum temperature | °C | / |
| Filter bag resistance | Pa | <900 |
| Filter bag life | Year | ≥5 |
| Emission standards | Mg/m3 | <10 |